leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into the circulation path...
Search Results "Path of Travel"
-
11B-307.2 Protrusion limits
-
307.2 Protrusion Limits
leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path...
-
11B-307.2 Protrusion limits
leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into the circulation path...
-
307.2 Protrusion Limits
leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into the circulation path...
-
206.2.8 Employee Work Areas
Common use circulation paths within employee work areas shall comply with 402. EXCEPTIONS: 1....
-
206.2.8 Employee Work Areas
Common use circulation paths within employee work areas shall comply with 402. EXCEPTIONS: 1....
-
13. Do the provisions for openings in floor and ground surfaces in Section 302.3 apply to walking surfaces in play areas?
If gratings or openings have elongated openings, they must be placed so the long dimension is perpendicular to the dominant direction of travel....
-
Scoping [4.1.2(3), 4.1.3(2)]
Requirements for protruding objects apply to all circulation routes, including both accessible and inaccessible routes and include corridors, walks, courtyards, stairways, and areas...
-
Development of Surface Roughness Standards for Pathways Used by Wheelchair Users: Final Report
Development of Surface Roughness Standards for Pathways Used by Wheelchair Users: Final Report December 2014 Human Engineering Research Laboratories VA Pittsburgh...
-
206.2.6 Performance Areas
Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area....
-
Dumpster Enclosures
The common use circulation path to the dumpster enclosure, however, shall not be required to comply with TAS 402 if the employee work area is fully exposed to the weather based on TAS 206.2.8...
-
F206.2.6 Performance Areas
Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area....
-
Technical Memorandum TM 2014-24 Location (Accessible Routes)
August 15, 2014 2012 TAS Reference: 206.3 In accordance with TAS 206.3, the location of accessible routes must coincide with or be located in the same area as the general circulation path...
-
11B-216.6 Entrances
Section 11B-703.7.2.1, indicating the accessible route to the nearest accessible entrance shall be provided at junctions when the accessible route diverges from the regular circulation path...
-
11B-216.6 Entrances
Section 11B-703.7.2.1, indicating the accessible route to the nearest accessible entrance shall be provided at junctions when the accessible route diverges from the regular circulation path...
-
206.2.6 Performance Areas
Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area....
-
F244.5.4 Location
Outdoor recreation access routes required by F244.5.2 and F244.5.3 shall coincide with or be located in the same area as general circulation paths. Advisory F244.5.4 Location....
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....
-
Exception for accessible means of egress in existing buildings in IBC 2000
1003.2.13 Accessible means of egress. Accessible means of egress shall comply with Sections 1003.2.13.1 through 1003.2.13.7.1. Accessible spaces shall be provided with not less...
- Beneficial Designs The Universal Trail Assessment Process (UTAP)
- New Horizons: Information for the Air Traveler with a Disability
-
Employee Work Areas [§206.2.8]
Employee Work Areas [§206.2.8] Common use circulation paths must be accessible in employee work areas that are 1,000 sq. ft. or more in size....
-
36 CFR Part 1190, Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Right-of-Way; Shared Use Paths (SNPRM)
Shared use paths are multi-use paths designed primarily for use by bicyclists and pedestrians, including pedestrians with disabilities, for transportation and recreation purposes....
-
403.5 Clearances
EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential to the...