If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
Search Results "Floor Slope"
-
§ 38.23(c)(5) Slope
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
§ 38.83(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
11B-309.2 Clear floor space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-309.2 Clear floor space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
Clear Floor or Ground Space: ADA Standard Section 902.2
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
When the surface of the clear ground space is constructed of concrete, asphalt, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
11B-302 Floor or ground surfaces
[See subsections ...]
-
11B-302 Floor or ground surfaces
[See subsections ...]
-
TEST NO. 2 – SITE ANALYSIS TEST
The analysis of the existing slope (before grading) shall be done on a topographic survey with 2-foot (610 mm) contour intervals with slope determination made between each successive interval...
-
TEST NO. 2 – SITE ANALYSIS TEST
The analysis of the existing slope (before grading) shall be done on a topographic survey with 2-foot (610 mm) contour intervals with slope determination made between each successive interval...
-
11B-411.2.3.1 Floor designation signs
Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-411.2.3.1 Floor designation signs
Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
A4.5.1 General
It is recognized that the coefficient of friction varies considerably due to the presence of contaminants, water, floor finishes, and other factors not under the control of the designer...
-
Rough Form and Foundation Inspection
building form elevations are set relative to site features (accessible routes, accessible parking, common and public use areas, and other site arrival points) to ensure correct accessible slopes...