R304.2.2 Running Slope....
Search Results "Floor Slope"
-
R304.2.2 Running Slope
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
Floor or Ground Surface: ADA Standard Section 1002.4.1
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
A4.8.2 SLOPE AND RISE
The ability to manage an incline is related to both its slope and its length....
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
4.8.2* Slope and Rise
The least possible slope shall be used for any ramp. The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
A4.8.2 Slope and Rise
Ramp slopes between 1:16 and 1:20 are preferred. The ability to manage an incline is related to both its slope and its length....
-
4.8.2* SLOPE AND RISE
The least possible slope shall be used for any ramp. The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
R404.2 Surfaces
Surfaces of clear spaces shall comply with R302.7 and shall have a running slope consistent with the grade of the adjacent pedestrian access route and cross slope of 2 percent maximum....
-
Slopes and Resting Intervals for Beach Access Routes
Running slope, also referred to as "grade," is the lengthwise slope of a beach access route, parallel to the direction of travel....
-
Submerged Depth: ADA Standard Section 1009.3.2
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
E1-4. Accessible Route Slope
Where the slope of the accessible route is greater than 1:20, does this part of the accessible route meet the following requirements for an accessible ramp? Yes _____ No _____...
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
1.1.10 Ramps
Measure accessible ramps for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with Sections 1.1.11, 1.1.12, 1.1.13...
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....