Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
Search Results "Examination Equipment"
-
M305.2.2.1 End Transfer Supports
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
M303 Diagnostic Equipment Used by Patients in a Wheelchair (Section-by-Section Analysis)
M303 in the final rule establishes the technical requirements for diagnostic equipment used by patients seated in a wheelchair, such as weight scales with wheelchair spaces and mammography...
-
255 Chapter 2: Scoping Requirements (Section-by-Section Analysis)
This chapter proposes scoping for requirements applicable to telecommunications equipment manufacturers in the design, development, or fabrication of covered ICT that is newly released,...
-
§ 1194.23(j)
(j) Products that transmit or conduct information or communication, shall pass through cross-manufacturer, non-proprietary, industry-standard codes, translation protocols, formats or...
- AbleData Factsheet: Is Your AT Considered Durable Medical Equipment?
-
Section 36.309 Examinations and Courses (Section-By-Section Analysis and Response to Comments)
Section 36.309 Examinations and Courses (Section-By-Section Analysis and Response to Comments) Section 36.309(a) sets forth the general rule that any private entity that offers examinations...
-
M101.1 Purpose
These Standards (MDE Standards) contain scoping and technical requirements for medical diagnostic equipment (diagnostic equipment) to ensure accessibility to, and usability of the diagnostic...
-
§1193.21 Accessibility, usability and compatibility.
Where readily achievable, telecommunications equipment and customer premises equipment shall comply with the requirements of subpart C of this part....
-
28 CFR Parts 35 and 36, Nondiscrimination on the Basis of Disability by State and Local Governments and Places of Public Accommodation; Equipment and Furniture (ANPRM)
RIN 1190-AA64 Nondiscrimination on the Basis of Disability by State and Local Governments and Places of Public Accommodation; Equipment and Furniture AGENCY: Department of Justice...
-
M101.2 Application
The standards shall be applied to diagnostic equipment based on the patient positions that the equipment is designed to support....
-
Section 1193.21 Accessibility, usability and compatibility (Section-by-Section Analysis)
Where it is not readily achievable to comply with Subpart C, telecommunications equipment and customer premises equipment shall comply with the provisions of Subpart D, if readily achievable...
-
IV. Description of Reporting, Recordkeeping and Other Compliance Requirements.
Manufacturers of telecommunications equipment and customer premises equipment are required by Section 255 to "ensure that the equipment is designed, developed and fabricated to be accessible...
-
Text Telephones (TTYs) (Advisory Guidance)
Text Telephones (TTYs) 20. A TTY also provides direct two-way typed conversations. The cost of these devices begins at approximately $200 and they can be operated by anyone who...
-
Alternate Modes (Advisory Guidance)
Alternate Modes 11. Information is provided increasingly through a variety of means including television advertisements, Internet postings, information seminars, and telephone....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.1.3 Transfer Surface Low Height Options for M301 and M302
5.1.3 Transfer Surface Low Height Options for M301 and M302 The Committee did not agree on a final low height recommendation. Rationale for final recommendation (more detail...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.