Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2....
Search Results "Equipment Console"
Commonly Searched Documents
-
M301.4 Lift Compatibility
-
M302.1 General
Where diagnostic equipment is used by patients in a seated position, it shall comply with M302....
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
-
M201.1 Application by Enforcing Authority
The enforcing authority shall specify the number and type of diagnostic equipment that are required to comply with the MDE Standards....
-
PART 4: ACCESSIBLE MEDICAL EQUIPMENT
Availability of accessible medical equipment is an important part of providing accessible medical care, and doctors and other providers must ensure that medical equipment is not a barrier...
-
M201.1 Enforcing Authority
The enforcing authority specifies the minimum number of types of accessible diagnostic equipment that are required to comply with the standards in different types of health care facilities...
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed to place the requirements for stirrups on diagnostic equipment used by patients in the supine, prone, or side-lying position in M301....
-
M305.5 Head and Back Support (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients in the supine, prone, or side-lying position and the seated position that can be adjusted to a reclined position to...
-
M301.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the supine, prone, or side-lying position in M301...
-
§1193.33(a)
(a) Manufacturers shall ensure access to information and documentation it provides to its customers. Such information and documentation includes user guides, installation guides for...
-
5.3.2 Transfer Sides Recommendations for M301
The provisions result in the transfer surface being located at a corner of the equipment and the two transfer sides adjoining at the edges of the equipment (e.g., foot of an examination...
-
M307 Operable Parts
M307 provides technical criteria for operable parts used by patients to activate, deactivate, or adjust the diagnostic equipment (see defined terms in M102.1)....
-
11B-405.5 Clear width
Exceptions: Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment...
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5....
-
Equipment and furniture.
obligations to provide accessible free-standing equipment, the Department was considering adding specific language on equipment. ...
- Selenia Dimensions Mammography System
- Selenia Performance Digital Mammography System
- Merlexi Craft™ Liberty MRI Wheelchairs
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
in the prone, supine, or side-lying position on certain types of equipment such as stretchers and imaging equipment with scanning beds....
-
M101.6 Dimensional Tolerances
Dimensions are subject to conventional industry tolerances for manufacturing processes, material properties, and field conditions.
-
Chapter 2: Scoping
[See subsections ...]
-
Section 1193.31 Accessibility and usability (Section-by-Section Analysis)
Section 1193.31 Accessibility and usability (Section-by-Section Analysis) This section provides that, subject to section 1193.21, manufacturers must design, develop and fabricate...
-
M307.3 Operation
Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist.
-
M307.1 General
Operable parts for patient use shall comply with M307.