If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
Search Results "Conference Room"
Commonly Searched Documents
-
806.2.4.1 Vanity Counter Top Space
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
L. Accessible Guest Rooms
Accessible Guest Rooms (1) Defendants will have 12 designated accessible rooms/ suites that comply with the 2010 Standards dispersed among the various classes of accommodations as follows...
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
4.35.5 Mirror
Where mirrors are provided in dressing rooms of the same use, then in an accessible dressing room, a full-length mirror, measuring at least 18 in wide by 54 in high (460 mm by 1370 mm),...
-
11B-224.1.1 Alterations
Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
-
Toilet Facilities and Bathing Facilities: ADA Standard Section 213
Section 213 covers scoping requirements in the current ADA Standards for toilet facilities and bathing facilities.
-
11B-213 Toilet facilities and bathing facilities
[See subsections ...]
-
11B-805.5 Patient change areas
Areas where patients change or are prepared for a procedure shall comply with Section 11B-222.
-
Toilet Rooms-Banquet Area
Toilet Rooms-Banquet Area: s....
-
9.2 Requirements for Accessible Units, Sleeping Rooms and Suites
[See subsections ...]
-
E. Smoking Rooms
E. Are smoking and non-smoking accessible guestrooms provided based upon the ratio of smoking and non-smoking guestrooms in the facility so persons with disabilities have the same...
-
4.3.5 HEAD ROOM
Accessible routes shall comply with 4.4.2.
-
Head Room [4.4.2]
Circulation paths must provide at least 80 inches of vertical clearance. Otherwise, fixed barriers detectable by canes must define areas with less clearance. Gates, rails, curbs, and...
-
Head Room [4.3.5]
The 80 inch minimum vertical clearance applies not only to accessible routes but to all circulation routes (see 4.4.2). Eighty-inch doors, including those equipped with closers, are...
-
4.3.5 Head Room
Accessible routes shall comply with 4.4.2.