Does the parking garage serving the lodging facility allow at least 98" of vertical clearance for vehicles with raised roofs to approach, use and exit the accessible parking spaces?...
Search Results "Floor-Level Exit Sign"
-
I. Parking Garage
-
A4
Is there vertical clearance of at least 114 inches (9 feet 6 inches) from the site entrance to the vehicle pull-up area, the access aisle, and along the vehicle route to the exit?...
-
4.1.3(8)(b) Note
Because entrances also serve as emergency exits whose proximity to all parts of buildings and facilities is essential, it is preferable that all entrances be accessible....
-
11B-805 Medical care and long-term care facilities
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1008.1.9.7, item 5.1 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
11B-708.2 Audible and visual indicators
Signs indicating the meaning of visual signals should be provided. ◼...
-
11B-708.2 Audible and visual indicators
Signs indicating the meaning of visual signals should be provided. ◼...
-
1136A.1 Receptacle heights
located no more than 48 inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level...
-
1136A.1 Receptacle heights
located no more than 48 inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level...
-
Catch Pools
An accessible means of entry or exit is not required into the catch pool. However, an accessible route must connect to the edge of the catch pool....
-
2. Are play components that have multiple stations or which can include more than one person using them at one time considered one or two play components?
If required to be accessible, a play component must be on an accessible route, have clear floor or ground space and maneuvering space, and have entry points and seats at the required heights...
-
1007.8 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
1003.2.13.7 Exterior area for assisted rescue
This construction shall extend vertically from the ground to a point 10 feet (3048 mm) above the floor level of the area for assisted rescue or to the roof line, whichever is lower....
-
B. Interior Ramps
(3) Third Floor North Corridor (Route to Fitness Center, Pool, and Spa) - This corridor will be modified so that its running slope does not exceed 1:20 (5%) or 1:12....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Raised Characters: ADA Standard Section 703.2
Signs that are designed to be read by touch should not have sharp or abrasive edges. ...
-
11B-216.10 Assistive listening systems
Assistive listening signs shall comply with Section 11B-703.5 _|Signs; Visual Characters|_ and shall include the International Symbol of Access for Hearing Loss complying with Section 11B...
-
11B-216.10 Assistive listening systems
Assistive listening signs shall comply with Section 11B-703.5 _|Signs; Visual Characters|_ and shall include the International Symbol of Access for Hearing Loss complying with Section 11B...
-
Separate Tenancies
This is required even where it would increase the minimum number above the number of required exits or 50% of facility entrances....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....
-
502.5 Vertical Clearance
underground parking as the primary available parking space shall design the covered or underground parking facility to maintain a minimum height for the portion of the street-accessible level...
-
ASME
The provisions for escalators require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches...