with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the ramped surface...
Search Results "Dining Surface"
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
1133A.2 Clear floor space
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
604.7 Dispensers
paper dispensers are installed above the side wall grab bar, the outlet of the toilet paper dispenser must be 48 inches (1220 mm) maximum above the finish floor and the top of the gripping surface...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
308.3.2 Obstructed High Reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
Alterations
Primary function areas include the dining area of a cafeteria, the meeting rooms in a conference center, the classrooms in a school, as well as offices and other work areas in which the...
-
Substitute cells. (Section-by-Section Analysis)
integrated with other cells to the maximum extent feasible, and has, at a minimum, physical access equal to that of the original cells to areas used by inmates or detainees for visitation, dining...
-
5.8.2.1 Height of Breast Platform at Time of Measurement
However, the top surface of the breast platform is a well-defined surface, and defines where the patient’s chest will be during the exam....
-
Alterations to Existing Facilities
For example, if an alteration project involves only installing pedestrian signals at existing intersections and there are no detectable warning surfaces on the curb ramps at the intersections...
-
Slopes and Resting Intervals for Beach Access Routes
When the surface is paved or is built with boards, the cross slope is not allowed to be steeper than 1:48 (2 percent)....
-
11B-1003.3.2 Boarding pier clearances
At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp....
-
1003.3.2 Boarding Pier Clearances
At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp....
- Bradley Towel Dispenser 250-33
-
1.1.3.2 State-regulated buildings, structures, and applications
of assemblage where 50 or more persons may gather together in a building, room or structure for the purpose of amusement, entertainment, instruction, deliberation, worship, drinking or dining...
-
1.3.1 Overview of NPRM
Types of Equipment to Which Technical Criteria Applies Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301) Transfer surface...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS Current accessibility standards and regulations generally consider a transfer surface...
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....