inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level of the finished floor...
Search Results "Ground Floor"
-
1136A.1 Receptacle heights
-
11B-809.10.7.3 Reinforcement for grab bars
comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
Lift Compatibility (M301.4 and M302.4)
Portable floor lifts have legs with wheels that need to fit under or around the base of the diagnostic equipment....
-
4.1.3 Adjustable Height Chairs with and without Footplates
4.1.3 Adjustable Height Chairs with and without Footplates Patients seated in adjustable height examination chairs typically rest their feet on the floor or on a footplate or have their...
-
How should we describe facilities that only meet some of the accessibility guidelines?
For instance, you can let people know that the main floor of the office is accessible but other floors can be reached by stairway only, and provide instructions on how to visit someone whose...
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
1017.4.1 Size
Where the passing space is the intersection of two trails, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground when turning into...
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
1017.4.1 Size
Where the passing space is the intersection of two trails, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground when turning into...
- Hussey Seating Company Roll-A-Way Seating
-
§ 1194.25(j)(3)
(3) Where any operable control is more than 10 inches and not more than 24 inches behind the reference plane, the height shall be 46 inches maximum and 15 inches minimum above the floor....
-
Mirrors
Provide a mirror in the Spy City Café men's and women's toilet rooms where the bottom edge of the reflecting surface of the mirror is mounted no more than 40" above the finished floor....
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
H27
Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor?...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to...
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....