Handrails that are not continuous must have horizontal extensions at both the top and bottom of the ramp at least 12 inches long that are rounded or returned smoothly to walls, posts, or floors...
Search Results "Ground Floor"
Commonly Searched Documents
-
Extensions
-
Vertical Wheelchair Lifts
The ASME code specifies a maximum travel distance of 12 feet and prohibits penetration of floors....
-
Scoping [4.1.3(21), 4.1.6(3)(h)]
In alterations, where this is not technically feasible, at least one accessible dressing room per floor is allowed for each sex (or one unisex room if that is the only type provided)....
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
5.2 FOOD SERVICE LINES
Tray slides shall be mounted no higher than 34 in (865 mm) above the floor. If self-service shelves are provided, a reasonable portion must be within the ranges shown in Fig. 53....
-
4.34.6.6* RANGES AND COOKTOPS
The clear floor space may overlap the knee space, if provided, by 19 in (485 mm) maximum. The location of controls for ranges and cook-tops shall not require reaching across burners....
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
Are closet doors and pantry doors required to comply?
cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage (§811), including those for clear floor...
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2....
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
ICC/IBC: ADA Standard Section 105.2.4
Section 105.2.4 of the ADA Standards cover references to the International Code Council (ICC) and the International Building Code (IBC).
- GameTime GT Jam Box for PrimeTime Playground Equipment
- Bradley Grab Bars 1 1/2" with Concealed Mounting 812
- AJW Architectural Products U703 Series 16"W x 24"H Adjustable Tilt Channel Frame Mirror - Plate Glass Surface
- AJW Architectural Products U704 Series 16"W x 30"H Fixed Tilt Angle Frame Mirror - Plate Glass Surface
- Neo-Metro Commercial Wall Mounted Metaal Basin 8937 Series
- NABCO GT1175 All Glass Sliding Door
- Hill-Rom Likorall™ 242 S Overhead Lift
- Easterseals North Texas
- Coastal Bend Center for Independent Living (CBCIL) - Corpus Christi, TX
-
Sales and Service Counters
At counters having a cash register, a section of counter at least 36 inches long and not more than 36 inches above the floor will make the counter accessible....
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...