(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge plate, or...
Search Results "Curb Ramp Surface"
-
§ 38.101(a)
-
608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
§ 38.119(a)
(a) Any stepwell, or doorway with a lift, ramp or bridge plate, shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread, ramp, bridge plate...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
A. No. The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2.
-
R302.3 Continuous Width
Except as provided in R302.3.1 and R302.3.2, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
R308.1.1.1 Dimensions
Boarding and alighting areas shall provide a clear length of 2.4 m (8.0 ft) minimum, measured perpendicular to the curb or street or highway edge, and a clear width of 1.5 m (5.0 ft) minimum...
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
502.2.1 On-street parallel parking
Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. Figure 502.2 Vehicle Parking Spaces...
-
203.6 Single Occupant Structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1003 Recreational Boating Facilities
This section provides requirements for gangways, boating piers at boat launch ramps, and boat slips....
-
§ 38.81(b)
(b) Other stepwells, and doorways with lifts, ramps or bridge plates, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread or lift or ramp, when deployed...
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
-
Two Step Transfers Attainable Heights
The 5th percentile of participants could transfer to a platform that was 2 inches lower than the first platform for both the adjacent and the ramp transfers....
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
§ 38.31(b)
(b) Other stepwells and doorways, including doorways in which lifts or ramps are installed, shall have, at all times, at least 2 foot-candles of illumination measured on the step tread,...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....
- Wheelchair Fitness Solution | Smart training system for wheelchair users