(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
Search Results "Clear Space"
-
§ 36.406(d)(1)
-
§ 35.151(e)(1)
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
406.6 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
- AD Systems’ Patient Restrooms
-
The carrier must designate priority stowage space for at least one wheelchair in the closet or other stowage area
other approved stowage area for passengers’ carry-on items of sufficient size to accommodate a folding, collapsible, or break-down wheelchair, the carrier must designate priority stowage space...
-
R308.1 Transit Stops
Where security bollards are installed at transit stops, they must not obstruct the clear space at boarding and alighting areas or reduce the required clear width at pedestrian access routes...
-
R405.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear space, the toe clearance shall extend 430 mm (1.4 ft) minimum under the element....
-
§ 36.406(d)(1)
(1) In sleeping rooms with more than twenty-five beds covered by this section, a minimum of five percent (5%) of the beds shall have clear floor space complying with section 806.2.3....
-
§ 35.151(e)(1)
(1) In sleeping rooms covered by this section with more than twenty-five beds, five percent (5%) minimum of the beds shall have clear floor space complying with section 806.2.3....
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not obstructed...
-
11B-809.10.6.1 Size
the same dwelling unit, at least one shower stall shall comply with one of the following: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep, clear...
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
4.7.10 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have 48 in (1220 mm) minimum clear space as shown in Fig. 15(c) and (d)....
-
Diagonal Curb Ramps [§406.6]
Diagonal Curb Ramps [§406.6] If curb ramps are placed diagonally at an intersection, it is important that clear space 48” long min. is available at the bottom that is outside active...
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...
-
Technical Requirements [1017]
The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
-
R309.5.2 Displays and Information
Displays and information shall be visible from a point located 1.0 m (3.3 ft) maximum above the center of the clear space in front of the parking meter or parking pay station....
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
- ADDitude Online Magazine