These include cerebral palsy, autism and type 1 diabetes. If current trials are successful, cord blood treatment may become a common practice within the next several years....
Search Results "Grade 1 Braille"
Commonly Searched Documents
- The Cord Blood Center
- CDHP: Quality Services for People with Disabilities and Activity Limitations
-
12207(b) Submission of Report
--Not later than 1 year after the enactment of this Act, the National Council on Disability shall submit the report required under subsection (a) to Congress....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
809.5.2 Residential Dwelling Unit Smoke Detection System
Residential dwelling unit smoke detection systems shall comply with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
11B-406.3.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
STANDARD BUILDING EVACUATION SYSTEMS
A standard building evacuation system has three components: 1. The circulation path 2. The occupant notification system(s) 3....
-
809.5.2 Residential Dwelling Unit Smoke Detection System
Residential dwelling unit smoke detection systems shall comply with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
Load and Unload Areas
Load and Unload Areas The floor or ground surface in the load and unload areas must have a slope not steeper than 1:48 and be stable, firm, and slip resistant....
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
T402.8.2 Deployment to Boarding Platforms
The running slope of ramps and bridgeplates used for deployment to platforms shall be 1:8 maximum, as measured to the boarding platform with the non-rail vehicle resting on a flat surface...
-
A6
If a curb ramp is provided, is the running slope of the ramp surface (not counting the side flares) no more than 1:12 or 8.33% [ADA Standards § 4.7.2] Yes No...
-
§104.33(b)(2)
Implementation of an Individualized Education Program developed in accordance with the Education of the Handicapped Act is one means of meeting the standard established in paragraph (b)(1)...
-
5. Curb Ramp Running Slope
5. ...do the curb ramps have running slopes of 1:12 or less (critical dimension of 2" or less)?...
-
7. Exterior Ramp Running Slope
7. ...do the exterior ramps have running slopes of 1:12 or less (critical dimension of 2" or less)?...
-
11B-504.4 Tread surface
Exception: Treads shall be permitted to have a slope not steeper than 1:48....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
4.2.1* Wheelchair Passage Width
The minimum clear width for single wheelchair passage shall be 32 in (815 mm) at a point and 36 in (915 mm) continuously (see Fig. 1 and 24(e))....
-
E1-4. Accessible Route Slope
Where the slope of the accessible route is greater than 1:20, does this part of the accessible route meet the following requirements for an accessible ramp? Yes _____ No _____...
-
4.2.1* WHEELCHAIR PASSAGE WIDTH
The minimum clear width for single wheelchair passage shall be 32 in (815 mm) at a point and 36 in (915 mm) continuously (see Fig. 1 and 24(e))....