However, that document also recognized an alternative "universal" design under which all spaces are designed to be accessible for vans or cars by incorporating additional space in the parking...
Search Results "Floor Designation"
-
Accessible Parking Space Width
-
T402 Ramps and Bridgeplates
Additional research directed at evaluating design loads for ramps in buses and vans, as well as potential effects of increase in minimum design load on vehicle design or operation is needed...
-
§ 36.302(f)(5)(i)(B)
(B) When all non-accessible tickets in a designated seating area have been sold and the tickets for accessible seating are being released in the same designated area; or...
-
§ 35.138(e)(1)(ii)
(ii) When all non-accessible tickets in a designated seating area have been sold and the tickets for accessible seating are being released in the same designated area; or...
-
F247.1 General
The Federal Trail Data Standards classify trails by their designed use and managed use.8 A trail has only one designed use that determines the design, construction, and maintenance parameters...
-
EQUIVALENT FACILITATION
The use of designs, products, or technologies as alternatives to those prescribed, resulting in substantially equivalent or greater accessibility and usability....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
106.5.3 Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
1193.23(a) (Advisory Guidance)
., some things will be readily achievable in the design phase which may not be in later phases), barriers to accessibility and usability must be identified throughout product design and...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...