On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
Search Results "Floor Designation"
-
11B-411.2.1.1 Location
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
1004 Exercise Machines
This section requires clear floor space for transfer to, or use of, exercise machines....
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
106.5.3 Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
1193.23(a) (Advisory Guidance)
., some things will be readily achievable in the design phase which may not be in later phases), barriers to accessibility and usability must be identified throughout product design and...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
Number of Accessible Entrances
The proposed rule required that at least one accessible entrance be a ground floor entrance (206.4.3)....
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
Workshop Objectives
developing guidelines towards design issues....
-
New Construction
New buildings and facilities must comply with the new construction provisions of the ADA Standards for Accessible Design (without the elevator exemption) or the Uniform Federal Accessibility...
-
Kitchen Appliances
Section 309 includes specifications for clear floor space (309.2), height (309.3), and operating characteristics (309.4)....
-
Conclusions
Results showed that transferring to a height similar to the average wheelchair seat to floor height of the sample (21”, 53.3 cm) is achievable by 95% of adult wheelchair users who independently...
-
G. Women's Spa and Fitness Center Locker Room
(2) Thereafter, the Royal Suite will be designated as the accessible spa treatment room and will be made available to customers requiring its accessible features at the same cost as...