[DSA-AC & HCD 1-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use...
Search Results "Enhanced 9-1-1"
-
ACCESSIBILITY
-
804.6.2 Operable Parts
EXCEPTIONS: 1. Appliance doors and door latching devices shall not be required to comply with 309.4. 2....
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
4(4)
Thresholds and changes in level at these locations are beveled with a slope no greater than 1:2....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
810.2.4 Slope
Perpendicular to the roadway, the slope of the bus stop boarding and alighting area shall not be steeper than 1:48....
-
303.1 General
EXCEPTIONS: 1. Animal containment areas shall not be required to comply with 303. 2. Areas of sport activity shall not be required to comply with 303....
-
4.21.7 Curbs
If provided, curbs in shower stalls 36 in by 36 in (915 mm by 915 mm) shall be no higher than 1/2 in (13 mm)....
-
United States of America v. Humboldt County, California - Settlement Agreement
CONSENT DECREE CIVIL ACTION NO. 1:16-cv-05139-NJV...
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
6.12 Handrails and Edge Protection
Where elevated dune crossings or dune crossings steeper than 1:20 (5 percent) are part of beach access routes, handrails complying with ABAAS section 505 and edge protection complying...
-
6.3 Minimum Number
At least one beach access route shall be provided for each 1/2 mile of shoreline where required by 6.2....
-
§ 37.213(a)
(a) This paragraph (a) applies to demand-responsive operators under §37.189 and fixed-route operators under §37.193(a)(1) that are required to, and small mixed-service operators under §37.191...
-
11B-812.3 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
§104.32 Location and notification.
[45 FR 30936, May 9, 2000, as amended at 65 FR 68054, Nov. 13, 2000] A recipient that operates a public elementary or secondary education program or activity shall annually:...
-
H. Drop-off Area Height
Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area?...
-
R405.3.1 General
Space under an element between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface shall be considered knee clearance and shall comply with R405.3....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....