5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to...
Search Results "Transfer Step"
Commonly Searched Documents
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
-
Clear Space Evaluation
nlike [sic] the first phase of the transfer study, subjects in this study were not impeded by any obstacles on the floor that limited the manner of which they approached the transfer station...
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are positioned...
-
M301.3.1 Transfer Supports
A) For transfer depths less than or equal to 24 inches a transfer support will be located opposite the transfer side....
-
11B-1002.5 Amusement ride seats designed for transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
11B-1002.5 Amusement ride seats designed for transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
11B-1002.5 Amusement ride seats designed for transfer
Advisory 11B-1002.5 Amusement ride seats designed for transfer....
-
I. Slip Resistant Surface—Aisles, Steps, Floor Areas Where People Walk, Floor Areas in Securement Locations, Lift Platforms, Ramps
Slip Resistant Surface—Aisles, Steps, Floor Areas Where People Walk, Floor Areas in Securement Locations, Lift Platforms, Ramps Slip resistance is based on the frictional force necessary...
-
M302.3.1 Transfer Supports
Transfer supports shall be provided for use with the transfer sides required by M302.2.3 and shall comply with M305.2....
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
could be repositioned during transfer....
-
6. Minimum (Low) Height Standard for Transfer Surfaces
Minimum (Low) Height Standard for Transfer Surfaces As indicated in Section 5.1.1, the MDE Advisory Committee recommends that equipment with transfer surfaces be height adjustable in...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
M302.3.1 Transfer Supports
Transfer supports shall be provided for use with transfer sides required by M302.2.4 and shall comply with M305.2.1.1, M305.2.2.1, and M305.2.3 through M305.2.8....
-
Ticket Transfers and Secondary Ticket Market
An individual with a ticket for an accessible seat may transfer it to anyone, including someone who does not have a disability....
- Figure 1009.4.2 Transfer Wall Height – Drawing from the U.S. Access Board
- EZ-ACCESS Transitions® Modular Entry Ramp
- SafePath BigHorn™ Ramps
- EZ-ACCESS Transitions® Modular Entry Mat
- EZ-ACCESS Transitions® Angled Entry Mat
- EZ-ACCESS Transitions® Angled Entry Plate
- Safepath EZ Edge™ Transition
-
12162(b)(2)(B)(iii)
(iii) a seat to which a passenger who uses a wheelchair can transfer....
-
242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
F242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....