At traffic islands, wheelchair space between opposing ramps is essential. If there is no level space between ramps, wheelchairs can "bottom out" or "high center" while proceeding...
Search Results "Raised Crossing"
Commonly Searched Documents
-
Islands [4.7.11]
-
11B-705.1.2.3 Islands or cut-through medians
11B-705.1.2.3 Islands or cut-through medians. Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2...
-
11B-203.3 Raised areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
11B-203.3 Raised areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
11B-203.3 Raised areas
Areas raised primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard...
-
1.1.2 Walks
Measure walks and other non - ramp pedestrian surfaces for overall running slope and cross slope as well as local running slope and cross slope variations (flatness) in accordance with 1.1.3...
-
1.1.4 Walk cross slope
1.1.4 Walk cross slope....
-
Cross Section of Gripping Surfaces
specify the following dimensions for grab bars to enable individuals with disabilities to firmly grasp the grab bars and support themselves during transfers: • Grab bars with circular cross...
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-406.5.1 Location
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
11B-407.2.3.1 Floor designation
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches (51 mm) high....
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
1017.7 Slopes
This section contains technical requirements for the maximum running slope and segment length (1017.7.1) and cross slope (1017.7.2) of trails....
-
Trail Slopes
Cross slopes that are too steep can be difficult to traverse, but trails with too little cross slope tend to become streams. Water running down or ponding on trails destroys them....
-
403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
11B-407.4.9 Emergency communication
Raised symbols or characters, white on a black background, and Braille shall be provided adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3....
-
403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
Colorado Cross-Disability Coalition, et al. Plaintiffs, v. Abercrombie & Fitch Co., et al., Defendants. - Statement of Interest on the Parties' Motions for Summary Judgment
IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF COLORADO Civil Action No. 09-cv-02757-WYD-KMT COLORADO CROSS-DISABILITY COALITION, et al. ...
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...