FEATURES: Weather resistant design allows interior or exterior application without adaptation UL® 15 amp. micro switch Crafted in clear anodized aluminum - will quote...
Search Results "Push Side"
Commonly Searched Documents
- Wikk Industries Ingress'r Automatic Door Control
- Wikk Industries Inc. PART# BPS SM-ING48 DB (710) with I36-3 Clear (628)
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
The transfer surface should be located such that the long dimension of 28 inches is located parallel to the patient scanning/imaging side of the table....
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
M301.2.2 Transfer Surface Size
When the transfer surface is located as described above in “A”, the width of the patient scanning/imaging table (side to side) at the designated transfer location should be 28 inches minimum...
-
Positioning Supports Considered
The Board is considering requiring in the final standards positioning supports such as rails, bars, or panels with handholds to be provided along the sides of diagnostic equipment used by...
-
4.3 Reach Ranges
Upper Side Reach Figure 19....
-
Clearances Around Gripping Surfaces
is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
5.4.1.2 Transfer and Positioning Support Location for Imaging Equipment
The transfer supports or positioning supports should be located opposite the transfer side....
-
M301.3.3 Head and Back Support
M301.3.3 Head and Back Support Proposed requirement: Where diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients...
-
Stirrups (M301.3.2)
Where stirrups are provided on diagnostic equipment used by patients in a supine, prone, or side-lying position, M301.3.2 would require the stirrups to provide a method of supporting, positioning...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Supports (M301.3, M302.3, and M305.2)
M301.3, M302.3, and M305.2 provide technical criteria for transfer and positioning supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic...
-
5.6.1 Stirrups Provision for M301
5.6.1 Stirrups Provision for M301 NPRM Description: For patients with limited leg strength and control, thigh, knee and calf supports are necessary to maintain an appropriate...
-
4.27.3* Height
The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
-
4.34.3(3) Forward and Parallel Approach
(3) Forward and Parallel Approach. If both a forward and parallel approach are possible, operable parts of controls shall be placed within at least one of the reach ranges in...
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
In the final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in...
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Figure 404.2.4.3(a) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
-
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings