The technical criteria in M301.2 and M302.2 address the height and size of the transfer surface, and the transfer sides....
Search Results "Intra-Family Transfer"
Commonly Searched Documents
-
Transfer Surface (M301.2 and M302.2)
-
5.2.2.2 Transfer Surface Depth
5.2.2.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
Implication for Standards and Design
The main difference between phase 1 and 2 relates to the tool used to collect the data on transfers. ...
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
5.2.2.1 Transfer Surface Width
5.2.2.1 Transfer Surface Width. The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
- EZ Launch for Kayaks and Canoes with Accessible Transfer Bench
-
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Accessibility Standards for Medical Diagnostic Equipment Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations - Imaging Equipment Final...
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface....
-
9. When ramp access is provided to one side of a crawl tube and the other side is only entered by transfer access, how is it counted (ramp or transfer access play component)?
When ramp access is provided to one side of a crawl tube and the other side is only entered by transfer access, how is it counted (ramp or transfer access play component)?...
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum....
-
Minimum Number: ADA Standard Section 234.3
Section 234.3 covers scoping requirements in the current ADA Standards for the minimum number of wheelchair spaces required at amusement rides.
-
(1) Adjustability: Minimum High Transfer Height
Therefore, transfer surfaces that are adjustable to a 25-inch maximum during patient transfer accommodate most patients who use mobility devices....
-
BACKGROUND
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support....
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side....
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer surfaces....
-
11B-1008.3.2.4 Contrasting stripe
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step. FIGURE 11B-1008.3.2 TRANSFER STEPS...
-
Study Objectives
The purpose of this study was to examine independent transfers to and from a WMD and a simple platform, with and without the use of grab bars and/or a backrest, and transfers between two...
-
Key Study findings:
wouldn’t attempt to transfer at all and 3 of which attempted the transfer but failed in the process). ...