Where the back of curb edge is tooled to provide a radius, the border dimension should be measured from the end of the radius....
Search Results "Absolute Dimension"
Commonly Searched Documents
-
R305.2 Placement
-
R103.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half is permitted....
-
Controls [4.21.5]
The dimensions for seats in 36 inch stalls are appropriate for seats in roll-in showers as well....
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
§ 38.23(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
Grab Bar Cross Sections
Non-circular cross sections were to have maximum cross section dimensions of 2 inches, a perimeter dimension between 4 and 4‒11/16 inches, and edges with a c inch minimum radius....
-
2.2 Key Measurement Variables and Procedures
Body and wheelchair dimensions: Approximately 125 locations of body and wheelchair points recorded in three dimensions. 3....
- SafePath: ADA Entry Level Landing Installation Training Video
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1011.2.4 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.10.9 Floor Plan of Elevator Cars
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
Dimensional Tolerances [3.2]
Recommendation: It is good practice to avoid specifying precisely to the maximum or minimum where possible so that achieved dimensions fall within ADAAG requirements....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
1011.2.4 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
§ 38.159(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
-
E101.4 Units of Measurement (Section-by-Section Analysis)
This proposed section is new to the 508 Standards and would clarify dimensions stated in the text of the proposed rule....
-
4.13.6 Maneuvering Clearances at Doors
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
8. Boarding Separately From Wheelchair
(Note, however, that under § 37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
8. Boarding Separately From Wheelchair
(Note, however, that under §37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle and...