Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
Search Results "Clear Width at Turn"
-
4.34.5.5(1) Size and clearances
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
Sections 35.171, 35.172, and 35.190--Streamlining Complaint Investigations and Designated Agency Authority (Section-by-Section Analysis)
The current language requires the agency to refer the complaint to the Department, which, in turn, refers the complaint. ...
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and...
-
Ticket distribution methods. (Section-by-Section Analysis)
The proposed rule makes clear that it is meant to reach all public accommodations that provide a service by which individuals can purchase event tickets, and is not limited to a venue's...
-
Ticket distribution methods. (Section-by-Section Analysis)
The proposed rule makes clear that it is meant to reach all public entities that provide a service or system by which individuals can purchase event tickets, and is not limited to a venue's...
- Clarity XLC2 Amplified Cordless Phone
- Clarity XLC3.4 DECT 6.0 Extra Loud Big Button Speakerphone with Talking Caller ID and ClarityLogic™
- ViewPlus Technologies VP Cub Braille Printer
-
Section 36.303(g)(1) Closed Movie Captioning
Other commenters disagreed, however, and stated that the Department should avoid using the term “closed captioning” to distinguish it from the “closed captioning” that is turned on at home...
-
704.3 Volume Control Telephones
If the microphone in the handset is not being used, a mute button that temporarily turns off the microphone can also reduce the amount of background noise which the person hears in the earpiece...
-
A. The Substantive Legal Dispute
Plaintiffs allege that Defendants' failure to install and maintain such pedestrian rights of way constitutes a systematic denial of meaningful access and discrimination that, in turn, violates...
-
224.7 Housing at a place of education
accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms with mobility features shall provide turning...
-
5. I am not open to the public, so I am not liable for accessibility.
In many cases, the assumption turns out to be incorrect, leaving the building owner and tenants at risk of violating the ADA....
-
Door and Gate Hardware [§404.2.7]
However, keys and access cards that are not part of the lockset are not required to comply (but those that do not require pinching or turning provide better access)....
-
Re: 405 Ramps
Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you....
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
§382.9(d)
provision of this part, and that the carrier has provided an effective alternative means of achieving the objective of the provisions of this part subject to the waiver or have demonstrated by clear...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
Define "task." (Section-by-Section Analysis)
The Department feels that the common definition of task is sufficiently clear and that it is not necessary to add to the definitions section. ...
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...