allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side reach shall be 15 inches (381 mm) minimum...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-308.3.1 Unobstructed
-
Legislation
Title V of the ADA mandated that the Architectural and Transportation Barriers Compliance Board (Access Board) set up minimum guidelines "to ensure that buildings, facilities, rail passenger...
- Allegion Von Duprin 33A/35A Series Exit Devices
- Caroma® USA Caravelle Smart 270 One Piece Toilet
- GE® 30" Slide-In Electric Convection Range JS750EFES
- Caroma® USA Sydney Smart 305 Easy Height Elongated 1 Piece Toilet
- Sloan WETS 2050.1001-1.28 Manual HET Flushometer and HET Wall Hung Water Closet
-
Re: Lavatories Adjacent to Partitions
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-223 Medical care and long-term care facilities
Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered or added until the number of patient bedrooms or resident sleeping rooms complies with the minimum...
-
Wheelchair Securement Systems
With respect to reducing the minimum design force for wheelchair securement systems, commenters to the 2010 NPRM expressed near universal support....
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
11B-904.4 Sales and service counters
the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum...
-
11B-224.4 Guest rooms with communication features
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES TOTAL NUMBER OF GUEST ROOMS PROVIDED MINIMUM NUMBER OF REQUIRED GUEST ROOMS WITH COMMUNICATION...
-
603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground....
-
1007.8 Exterior area for assisted rescue
rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall be constructed as required for a minimum...
-
308.3.1 Unobstructed
allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum...
-
Boarding Pier Clearances
There is no minimum length for the pier. However, the accessible boarding pier should be at least as long as other piers provided at the facility....
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the platform opposite the entry ramp and a minimum...
-
Protruding Objects [1016.9]
To prevent injuries to people who are blind or have low vision, whenever possible, maintain the vertical clearance free of tree branches a minimum of 80 inches above the ground surface along...
-
704.10 Vertical exposure
Exception: Opening protectives are not required where the roof construction has a fire-resistance rating of not less than 1 hour for a minimum distance of 10 feet (3048 mm) from the adjoining...
-
1003.2.13.7 Exterior area for assisted rescue
rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or unprotected opening shall be constructed as required for a minimum...