[2010 ADAS] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are...
Search Results "Local Building Code"
Commonly Searched Documents
-
11B-405.2 Slope
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
11B-206.2.6 Performance areas
For example, requiring persons with disabilities to go outside the building and reenter the building to gain access the stage when others have a direct route would not be considered coinciding...
- Besam Hurricane Resistant Automatic Sliding Door
- Blueraven Creative SensoryPEN™ for Exhibits and Audio Tours
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
SECTION 1008 DOORS, GATES AND TURNSTILES
SECTION 1008 DOORS, GATES AND TURNSTILES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where...
-
Accessible Route
Accessible Route - A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....
-
206.6 Elevators
In a building or facility permitted to use the exceptions to 206.2.3 or permitted by 206.7 to use a platform lift, elevators complying with 408 shall be permitted. 2....
-
F206.6 Elevators
In a building or facility permitted to use the exceptions to F206.2.3 or permitted by F206.7 to use a platform lift, elevators complying with 408 shall be permitted. 2. ...
-
CONCLUSION
In addition, it will build on the growing percentage of providers voluntarily purchasing accessible, adjustable height tables....
-
907.2.7 Group M
Exception: Manual fire alarm boxes are not required if the building is equipped throughout with an automatic sprinkler system and the alarm notification appliances will activate upon sprinkler...
-
Requirement 4. Accessible route into and through the covered dwelling unit.
Section 100.205(c)(3)(i) provides that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
APPENDIX
This appendix contains additional information that should help the designer to understand the minimum requirements of the standard or to design buildings or facilities for greater accessibility...
-
GRIEVANCE PROCEDURE
City of Waukegan will adopt the attached ADA Grievance Procedure (Attachment B), distribute it to all agency heads, and post copies of it in conspicuous locations in each of its public buildings...
-
5.1 Costs Included
The direct or "hard" costs shall not be reduced by the value of components, assemblies, building equipment or construction not directly associated with accessibility or usability....
-
ADA Regulations
They also address existing facilities and topics beyond building design, including access to programs, services, and communication and provision of auxiliary aids and services....
-
Clear Floor or Ground Space and Turning Space
Provisions throughout the standards reference these basic “building block” requirements....
-
68.60. Notice of Substantial Compliance
Department shall provide a Notice of Substantial Compliance to the owner, at the owner’s request through submission of a Notice of Substantial Compliance Request Form, after a newly constructed building...
-
GRIEVANCE PROCEDURE
an ADA Grievance Procedure, which has been approved by the Department, and will distribute it to all agency heads, and post copies of it in conspicuous locations in each of its public buildings...
-
PUBLIC USE
Public use may be provided at a building or facility that is privately or publicly owned....
-
2. The Class Notices Are Defective and Will Reach Only A Minuscule Portion of Class Members
As the summary notice of the Agreements advises, class members: "are deemed to have waived the protection provided by any state statutes or codes with respect to unknown claims at the...
- HEWI Panic Bar EN 1125
-
11B-212.3 Sinks
Scrub sinks, as defined in California Plumbing Code Section 221.0, shall not be required to comply with Section 11B-606....