In addition to the requirements of this chapter, means of egress, which provide access to, or egress from, buildings for persons with disabilities, shall also comply with the requirements...
Search Results "Local Building Code"
Commonly Searched Documents
-
1009.1 Accessible means of egress required
-
68.93. Complaints, Investigations, and Audits
A complaint may be filed against an owner if there is reason to believe that a building or facility is not in compliance with the Act, the rules, or the TAS....
-
Visual Alarms
Result: People who are deaf have no way of knowing that a building emergency has been declared while others who can hear are alerted by the audible alarm....
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
11B-206.4 Entrances
Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not...
-
3. Maintenance of Accessible Features
those features that are necessary to provide access to services, programs, and activities -- including elevators and lifts, curb ramps at intersections, accessible parking spaces, ramps to building...
-
21. New construction
If an alteration is undertaken to a portion of a building the accessibility of which could be improved by the manner in which the alteration is carried out, the alteration must be made in...
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
-
II-3.10000 Maintenance of accessible features
ILLUSTRATION 1: It would be a violation for a building manager of a three-story building to turn off the only passenger elevator in order to save energy during the hours when the building...
-
11B-504.8 Floor identification
11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
11B-504.8 Floor identification
11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings...
-
II-1.3000 Relationship to title III
ILLUSTRATION 2: A city owns a downtown office building occupied by its department of human resources....
-
II-6.3100 General principles
UFAS: If a building undergoes a "substantial alteration" (where the total cost of all alterations in a 12-month period amounts to 50% or more of the value of the building), the public entity...
- Great Lakes ADA Center
-
Play areas. (Section-by-Section Analysis)
State and local governments may have already adopted accessibility standards or codes similar to the 2004 ADAAG requirements for play and recreation areas, but which might have some differences...
-
BACKGROUND
The parties to this Settlement Agreement ("Agreement") are the United States of America (the "United States") and the Fill Building Associates, LLC, d/b/a Fill Building East ("FBE"), owner...
-
FOREWORD
User groups are petitioning State legislatures and local governments to legally operate their nonmotorized vehicles on roadways....
- Landscape Forms Inc. MutipliCITY Trash Receptacle
- BEST Keypad EZ Door Hardware
-
SECTION 1012 HANDRAILS
SECTION 1012 HANDRAILS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
SECTION 1009 STAIRWAYS
SECTION 1009 STAIRWAYS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility...
-
SECTION 1017 AISLES
SECTION 1017 AISLES [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is...
-
12204(c)(2) Sites eligible for listing in national register
.-- With respect to alterations of buildings or facilities that are eligible for listing in the National Register of Historic Places under the National Historic Preservation Act (16 U.S.C...
-
1007.7.6 Stairway
Exception: The clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...