and sign in Place sign check-in equipment on a side table or use a clipboard Install a lower countertop or lower a section of the existing counter Facility has two floors...
Search Results "Ground Floor Exit"
-
4.2 Physical Accessibility Barriers and Solutions
-
Door and Gate Hardware [§404.2.7]
must: allow one-hand operation not require tight grasping, pinching, or twisting of the wrist operate with 5 lbf maximum be located 34” to 48” above the floor...
- American Specialties Adjustable Tilt Mirror 0600T
-
11B-1008.2.5.2 Elevated
ETA Editor's Note The above restrictions on ramp slope for ramps connecting ground level play components, and on ramp rise for ramps connecting elevated play components, are more stringent...
-
11B-1008.2.5.2 Elevated
ETA Editor's Note The above restrictions on ramp slope for ramps connecting ground level play components, and on ramp rise for ramps connecting elevated play components, are more stringent...
-
4.29.3* TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Such textured surfaces shall not be provided for emergency exit doors or any doors other than those to hazardous areas....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area at the exterior side of the primary entry door and any required exit doors shall comply with Section 1126A. Notes: 1....
-
Signal Type: ADA Standard Section 407.4.8.2.1
Section 407.4.8.2.1 covers the current ADA Standards for the signal type of audible elevator car indicators.
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...
-
11B-809.10.6.4 Reinforcement for grab bars
grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor...
- Federal Elevator 360 Passenger Elevator
- Takeform Fusion Signage Evacuation Map Type D
-
STEP 3 Compare which is greater
STEP 3 Compare which is greater Step 3 compares your results in identifying the number and different types of ground level play components with those required by Table 240.2.1.2. ...
- Bradley Advocate AV-Series Model AV30 Lavatory, Soap & Hand Dryer Informational Video
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
5.8.2.5 Toe Height Recommendation
the ground....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Control buttons shall be located no higher than 48 inches (1219 mm) above the ground surface adjacent to the pole....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area at the exterior side of the primary entry door and any required exit doors shall comply with Section 1126A. Notes: 1. ...
-
7. Should overhead play components such as track riders, ring ladders, monkey bars, and chin up bars be lowered to the recommended reach ranges?
Overhead play components that are required to have their entry and exit points connected by an accessible route are not required to be lowered to be considered accessible....
-
1007.6.4 Instructions
Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
USE OF THE WAY
Once notified, people who are deaf or hard of hearing can read and follow standard exit and directional signs and use any standard means of egress from the building....
-
Multiple Usable Entrances
Several commenters noted that the Guidelines do not provide more than one accessible entrance/exit, and that without a second means of egress, wheelchair users may find themselves in danger...