Trim Style and Depth: Recessed - 3/8" flat trim or trimless.Semi-Recessed - 1 1/4", 1 1/2" Square Edge or 2 1/2", 3", 4"(Recessed Pull), 4 1/2" Rolled Edge. ...
Search Results "Maximum Reach Depth"
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
- BEA Inc. LZR-Microscan Swinging Door Sensor
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
From Dribbling Newbie to Hoop Hero: Your Guide to Mastering Basketball Stars
But don't be fooled by the simplicity – there's a surprising amount of depth involved. You’ll need to master the art of shooting, dribbling, stealing, and blocking....
-
410.6 Doors and Gates
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
Slope
A commenter recommended increasing the cross slope requirement to allow a maximum of ½ inch per foot (1:24) to prevent imperfections in concrete surfaces from ponding water....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-810.2.3 Connection
alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb with the face sloped at 35 degrees maximum...
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
1007.6 Areas of refuge
The maximum travel distance from any accessible space to an area of refuge shall not exceed the travel distance permitted for the occupancy in accordance with Section 1015.1....
-
404.2.11 Vision Lights
adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
A. Accommodations For Handicapped Students
Recipients must place secondary level handicapped students in the regular educational environment of any vocational education program to the maximum extent appropriate to the needs of the...
-
1003.2.13.5 Areas of refuge
The maximum travel distance from any accessible space to an area of refuge shall not exceed the travel distance permitted for the occupancy in accordance with Section 1004.2.4....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (815 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
405.9 Edge Protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area...
-
407.9 Operation (Section-by-Section Analysis)
The force required to activate operable parts would be limited to 5 lbs. (22.2 N) maximum....
-
208.1.2
208.1.2 A facility that is making alterations under section 202 as required by s.303(a) of the Americans with Disabilities Act of 1990 must comply with section 208 to the maximum extent...
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be permitted to be reduced to 32 inches (813 mm) minimum for a distance of 24 inches (610 mm) maximum provided...
-
10.3.1(1)
The circulation path, including an accessible entrance and an accessible route, for persons with disabilities shall, to the maximum extent practicable, coincide with the circulation path...
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
Handrails may be located in a recess if the recess is a maximum of 3 in (75 mm) deep and extends at least 18 in (455 mm) above the top of the rail (see Fig. 39(d))....
-
7.4.10.2 Outdoor Recreation Access Routes (ORARs)
In alterations to existing trailheads, where a condition for exception prohibits compliance with a technical provision, the ORAR shall comply with FSORAG 2.0 to maximum extent practicable...
-
§1630.1(c)(4) Broad coverage
Amendments Act's purpose of reinstating a broad scope of protection under the ADA, the definition of “disability” in this part shall be construed broadly in favor of expansive coverage to the maximum...