In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made concerning...
Search Results "Water Closet Clear Floor Space"
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made concerning...
-
Clear Floor Space
Clear floor spaces for inmates who use mobility devices...
-
11B-902.2.1 Overlap
The clear floor space at dining surfaces shall not overlap the accessible route....
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
4.16.1 General
Accessible water closets shall comply with 4.16....
-
Plan 4B: 13-Foot Wide Accessible Guest Room
closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space...
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
Installation: ADA Standard Section 609.7
Section 609.7 covers the current ADA Standards for the installations of grab bars.
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-604 Water closets and toilet compartments.
11B-604 Water closets and toilet compartments....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
Clear Floor Space [4.19.3]
Clear Floor Space [4.19.3] Clear floor space should be centered at the fixture (although this is not specifically required by ADAAG)....