Specifications for roll-in shower compartments indicate that an accessible lavatory can overlap the required clear floor space opposite the end with a seat and shower controls (608.2.2)....
Search Results "Water Closet Clear Floor Space"
-
Overlapping Clear Floor Space
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided. [ECTCR UFAS 4.18.3]...
-
§382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
Plan 3B: 12-Foot Wide Accessible Guest Room
); • Recessed lavatory with vanity counter top permits shorter rear grab bar at water closet (section 604.5.2); • Clear floor space adjacent to shower min. 30 inches wide by 60 inches...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
); • Recessed roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Clear floor space adjacent to shower min. 30 inches wide by 60 inches long...
-
Plan 6B: 12-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. [2010 ADAS] Advisory 407.2.1.3 Clear Floor or Ground Space. ...
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. [2010 ADAS] Advisory 407.2.1.3 Clear Floor or Ground Space....
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
1002.5.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
1002.5.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
2.3 Restrooms
Are the restrooms accessible? Is the entry door at least 32 inches wide? Is there a larger stall or an area in the restroom at least 36 inches in...
-
Plan 6A: 12-Foot Wide Accessible Guest Room
• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline...
-
604 Water Closets and Toilet Compartments
604 Water Closets and Toilet Compartments...
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided....
-
11B-605.3 Clear floor space
11B-605.3 Clear floor space. A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Water Closet Location.
Water Closet Location. ...
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....