2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
Search Results "Turning Space"
Commonly Searched Documents
-
2) Where the Standard says "Changes in level are not permitted"
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Clear Floor or Ground Space: ADA Standard Section 1005.4
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
2.6.1.2
The intersection of two outdoor recreation access routes providing a T-shaped space complying with ABAAS section 304.3.2 where the base and the arms of the T-shaped space extend 48 inches...
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
Clear Floor or Ground Space: ADA Standard Section 1002.5.1
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
Clear Floor or Ground Space: ADA Standard Section 903.2
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
Transfer Space: ADA Standard Section 1008.3.1.3
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform....
-
5.3.2.2 Surface
The surface of the turning space and clear floor or ground space shall be firm and stable. ...
-
R306.5 Channelized Turn Lanes at Other Signalized Intersections
R306.5 Channelized Turn Lanes at Other Signalized Intersections....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with 302. Changes in level are not permitted....
-
11B-304.2 Floor or Ground Surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
Bedside Clearances
Where more than one bed is provided, this space can overlap. Privacy curtains or screens that can be easily moved out of the way can also overlap this clearance....
-
11B-304.2 Floor or ground surfaces
Floor or ground surfaces of a turning space shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
Doors [4.35.3]
Doors cannot swing into the turning space (as allowed in toilet and bathrooms because they are larger)....
-
R304.5.3 Cross Slope
The cross slope of curb ramps, blended transitions, and turning spaces shall be 2 percent maximum....
-
2. a. iv. Path-of-Travel (wheelchair) space allowances
If a 180° turn is needed to exit an area, then a 60” diameter turning space or a 36” wide "T" is needed (see Figure 11)....
-
Clear Floor or Ground Space: ADA Standard Section 804.6.1
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....