An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
Search Results "Turning Space"
-
403.5.3 Passing Spaces
-
403.5.3 Passing Spaces
An accessible route with a clear width less than 60 inches (1525 mm) shall provide passing spaces at intervals of 200 feet (61 m) maximum....
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
4.3.5.4 360-degree Turn
Scooters require the largest turning spaces and manual chairs the least although there are some manual chair users that required spaces as large as many power chair users....
-
Is turning space required in all rooms and spaces?
Turning space is required in certain spaces, such as toilet and bathing facilities, dressing and fitting rooms, and transient lodging guest rooms....
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 360-degree turn....
-
3.3.13 360-Degree Turn
3.3.13 360-Degree Turn The standards on the space requirements for a 360-degree turn are quite similar across countries, ranging from 1500 mm (59 in.) in Canada and the U.K. to 1525...
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
4.3.4 Passing Space
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
4.3.4 PASSING SPACE
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
11B-603.2.3 Door swing
Clarifies that doors to accessible toilet compartments are allowed to encroach over required turning space without limitation. 11B-603.2.3 Door swing....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
- Access Board: T-Shaped Space
-
Clear Floor or Ground Space: ADA Standard Section 305
Section 305 covers the current ADA Standards for clear floor or ground space.
-
1010.1 Turning Space
1010.1 Turning Space. A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions. ...
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
6.3(1)
(1) Each bedroom shall have a turning space that complies with 4.2.3, and preferably that is located near the entrance....
-
Clear Floor Space: ADA Standard Section 410.3
Section 410.3 covers the current ADA Standards for clear floor space in platform lifts.
-
§ 38.29(a)
(a) Interior handrails and stanchions shall permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a securement location from the lift or ramp....
-
Width [4.3.3.] and Passing Space [4.3.4]
However, the minimum width of hallways and corridors is often further determined by ADAAG requirements for clear floor space at elements such as drinking fountains, door maneuvering clearances...
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3