403.5.2 Clear Width at Turn....
Search Results "Turning Space"
Commonly Searched Documents
-
403.5.2 Clear Width at Turn
-
Clear Floor Space [4.35.2]
Clear Floor Space [4.35.2] Clear floor space is required for a parallel approach to the bench....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
180 Turns Around Obstructions
Additional clearance is required at 180 degree turns around an element that is less than 48” wide....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
Water Hydrants
The surface at the base of water hydrants at recreation areas must be firm and stable with a 60-inch turning radius. See the "Surfaces" rule of thumb above....
-
Multi-Lane Channelized Turn Lanes (Section-by-Section Analysis)
Multi-Lane Channelized Turn Lanes (Section-by-Section Analysis) Pedestrian activated signals must be provided at pedestrian street crossings at multi-lane channelized turn lanes at roundabouts...
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
Clearance
Wider clearances are specified for wheelchair passing space (60 inches minimum) and certain sharp turns around narrow obstructions....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn,...
-
11B-603.2.3 Door swing
Doors to accessible water closet compartments shall be permitted to encroach into the turning space without limitation....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
This data depicts the amount of space required by users of wheeled mobility devices to perform a 180-degree turn....
-
6.3(2)
(2) Each bedroom shall have adequate space to provide a maneuvering space that complies with 4.2.3. In rooms with 2 beds, it is preferable that this space be located between beds....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. Exceptions: 1. ...
-
Clear Floor Space: ADA Standard Section 611.2
Section 611.2 covers the current ADA Standards for the clear floor space at washing machines and clothes dryers.
-
5.3.2.2 Surface
The surface of the turning space and clear floor or ground space shall be firm and stable....
-
Camp Shelters
One full, unobstructed side of the clear ground space must adjoin or overlap the trail or outdoor recreation access route (as applicable) or another clear ground space....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn Around Barrier
This data depicts the amount of space required by users of wheeled mobility devices to perform a 180-degree turn ("U-Turn") around an obstruction....
-
3.4.7 Openings
Openings in the clear ground space and turning space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....