Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
Search Results "Sliding Door"
-
11B-206.5.1 Entrances
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
Two Step Transfer Evaluation
The evaluation of two-step transfers has never been studied before and was evaluated in this phase. The two-step transfers consisted of an adjacent transfer (no gap between two...
-
Reopening Device: ADA Standard Section 407.3.3
Section 407.3.3 covers the current ADA Standards for elevator reopening devices.
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
- Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door
-
AD Systems’ Door-Sliding - Single -Two Sidelites
Requires the Premium User plan or above. (Login or upgrade your account!)
-
AD Systems’ Door-Sliding - Single - One Sidelite
Requires the Premium User plan or above. (Login or upgrade your account!)
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
- Besam SL500 Surface Mount Automatic Sliding Door - BP Narrow Stile BIM
- Besam SL500 Telescopic Automatic Sliding Door - Full Breakout Bi-part BIM
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Nana Wall Systems, Inc. Sliding Glass Walls With Solid Wood HSW66
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Clear Width: ADA Standard Section 404.3.1
Section 404.3.1 covers the current ADA Standards for clear width at automatic and power-assisted doors and gates.
-
Automatic Doors and Power Assisted Doors [4.13.12]
Automatic Doors and Power Assisted Doors [4.13.12] Automated doors are classified by industry standards according to the level of force produced by the door opening....
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....