The provisions of the California Mechanical Code shall apply to the installation of gas piping from the point of delivery, gas appliances and related accessories as covered in this code....
Search Results "Military Installation"
Commonly Searched Documents
-
[A] 101.4.1 Gas
-
101.4.1 Gas
The provisions of the California Mechanical Code shall apply to the installation of gas piping from the point of delivery, gas appliances and related accessories as covered in this code....
-
There is some confusion about whether the “accessible path” that is required means there must be an accessible path from the EVSE (charger) to the facility/building at which the station is installed, or whether the accessible path is just from the parking spot to the EVSE (charger). If the prior is enforced, it could increase the costs of installing EVSE in some instances. What is the correct interpretation of “accessible path”?
RESPONSE: The term used in the CBC is “accessible route.” EVCS required by CBC Chapter 11B to be accessible must have both, an accessible route to the facility entrance (see CBC...
-
1134A.7 Water closets
Where the water closet is placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
[A] 101.4.1 Gas
The provisions of the California Mechanical Code shall apply to the installation of gas piping from the point of delivery, gas appliances and related accessories as covered in this code....
-
A4.27.3 Height
Electrical receptacles installed to serve individual appliances and not intended for regular or frequent use by building occupants are not required to be mounted within the specified reach...
-
Can platform lifts be portable or provided after construction as an adaptation?
Platform lifts must be permanent and installed at the time of construction or alteration with few exceptions....
-
Can ramps be portable or provided after construction as an adaptation?
All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
-
907.2 Where required
Where automatic sprinkler protection, installed in accordance with Section 903.3.1.1 or 903.3.1.2, is provided and connected to the building fire alarm system, automatic heat detection required...
-
Temporary Solutions for Election Day
Suggestion: Install a portable ramp with edge protection. A portable ramp with edge protection is installed over a curb to provide an accessible route....
-
Findings
Deficiencies, such as excessive running slope, cross slope, changes in level, and openings for PIP, TIL and HYB began to emerge 24‒36 months after installation....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Installing flashing alarm lights. Widening doors. Installing offset hinges to widen doorways. Eliminating a turnstile or providing an alternative accessible route....
-
Observations and Results
Field Observation The park manager conducted a series of surveys of play surface users within 1 month of installation....
- TownSteel CD/CDC Series, Grade 1 Cylindrical Locks
- Wheelchair Fitness Solution™ Complete Fitness System
- Durateq® Handheld ATV (Assistive Technology Version) Device
-
A7.2(3) Assistive Listening Devices
service counters, teller windows, box offices, and information kiosks where a physical barrier separates service personnel and customers, it is recommended that at least one permanently installed...
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
-
[2010 ADAS] 105.2.5 NFPA
(4) Smoke alarms or smoke detectors shall be installed a minimum of 20 feet horizontal distance from a permanently installed cooking appliance....
-
405.2 Slope (Exception 2), 405.6 Rise (Exception)
of an entry ramp complying with the slope and rise requirements at emergency transportable housing units installed on private sites provided by the occupant of the unit....
-
4.1.3(19)(b)
Such assembly areas, if (1) they accommodate at least 50 persons, or if they have audio-amplification systems, and (2) they have fixed seating, shall have a permanently installed assistive...
-
New Rides
If the ride was purchased from another entity, “new” is the first permanent installation of the ride, whether it was purchased “off the shelf” or modified before installation....
-
12183(b) Elevator
(b) Elevator Subsection (a) of this section shall not be construed to require the installation of an elevator for facilities that are less than three stories or have less than 3,000 square...