The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception of imaging equipment....
Search Results "Flared Side"
Commonly Searched Documents
-
5.2.1.2 Transfer Surface Depth
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. ...
-
M301.2.1 Transfer Surface Height
The table side covers have the same issues discussed for the CT table in Figure 5.3-1....
- Midmark 647 Barrier-Free® Power Podiatry Procedures Chair
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
M305.2.3 Fittings
M305.2.3 Fittings Proposed requirement: Transfer supports shall not rotate within their fittings • Sub-Committee Recommendation: Transfer supports shall not rotate within...
-
5.5 Food Service Lines
Food service lines shall have a minimum clear width of 36 in (915 mm), with a preferred clear width of 42 in (1065 mm) to allow passage around a person using a wheelchair. Tray...
-
5.2 FOOD SERVICE LINES
Food service lines shall have a minimum clear width of 36 in (915 mm), with a preferred clear width of 42 in (1065 mm) where passage of stopped wheelchairs by pedestrians is desired....
-
Overhead Lifts
The technical criteria do not address overhead lifts that are usually mounted on the ceiling and operate on tracks suspended over the diagnostic equipment because the configuration...
-
Clearance in Base (M301.4.1 and M302.4.1)
Clearance in the base of the equipment allows the legs of a portable floor lift to fit under the base of the equipment. The clearance can be an open area between the supporting posts...
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed to place the requirements for stirrups on diagnostic equipment used by patients in the supine, prone, or side-lying position in M301....
-
M301.3.1 Transfer Supports
Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2....
-
5.2.1.1 Transfer Surface Width Recommendations for M301
5.2.1.1 Transfer Surface Width Recommendations for M301 The Committee recommends a transfer surface of 28 inches minimum width for equipment used by patients in a supine, side-lying,...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1....
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
- Moen Home Care Peened 42" Grab Bar
- Bobrick 42" Straight Grab Bar B-6806 x 42
- Bobrick 42" Straight Grab Bar B-5806 x 42
- Bobrick 42" Straight Grab Bar Peened B-5806.99 x 42
- Bobrick 42" Straight Grab Bar Peened B-6806.99 x 42
- Just Manufacturing 42" Stainless Steel Grab Bar