The 351 Powerglide® line of surface door closers has been engineered to meet the demands of architects and building owners....
Search Results "End-Opening Door"
- Sargent 351 Series Aluminum Door Closer
- TownSteel TDC 70 ALUMINUM Grade 1 Door Closer
- Cal-Royal CR801 Series Hydraulic Door Closers
- Sargent 281 Series Cast Iron Door Closer
-
4.6.7 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
- Yale 5800 Series Cast Iron Door Closer
-
Minimum Clear Opening
The issue of minimum clear opening for doors was one of the most widely commented-upon design features of the guidelines....
- TownSteel TDC 40, CAST IRON Grade 1 Door Closer
-
Automatic Doors
Provisions in section 404.3 address clear width; maneuvering clearance; thresholds; doors and gates in series; operable parts; break out opening; and revolving doors, gates, and turnstiles...
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
- Corbin Russwin Inc. DC6000 Series Cast Iron Door Closer
-
Compartment Doors
Specifications are provided for doors, including their location....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 ....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
- Yale 2700 Series Architectural Door Closer
-
Openings in Outdoor Recreation Access Route Surfaces
Openings are gaps in the surface of an outdoor recreation access route. Gaps include spaces between the planks on a boardwalk or in a drainage grate....
- Stanley QDC 200 Series Grade 1 Heavy Duty Door Closers
- Stanley QDC 300 Series Grade 1 Standard Duty Door Closers
-
12162(a)(2)(B)(i)
(i) be able to be entered by an individual who uses a wheelchair;