[§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in a jail or prison, are exempt from requirements for hardware...
Search Results "Compartment Hardware"
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
-
General
A commenter recommended that more than one wheelchair accessible compartment be provided in toilet rooms serving airports and train stations because these compartments are likely to be occupied...
-
Shower Compartments
Shower Compartments....
-
11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
[See subsections ...]
-
11B-604 Water closets and toilet compartments
[See subsections ...]
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
H17
H17. Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No
-
11B-604.9 Water closets and toilet compartments for children's use
SECTION TITLE NOTES 11B-604.9 Water closets and toilet compartments for children's use....
-
C. Doors
Yes __ No __ N/A __ Comments: ___________________________________________ ...with the exception of non-accessible guestrooms, does at least one door to each accessible space have door hardware...
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Baby Changing Tables
Commenters noted that baby changing tables should not be permitted in accessible compartments since they can interfere with access....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction. Where drains are provided, grate openings shall be ¼ inch...
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction. Where drains are provided, grate openings shall be ¼ inch...
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment. Figure 604.8.2 Ambulatory Accessible Toilet Compartment...
-
§ 38.127(a)
(a) Sleeping compartments required to be accessible shall be designed so as to allow a person using a wheelchair or mobility aid to enter, maneuver within and approach and use each element...
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall not be located in toilet compartments complying with Section 11B-604.8 or urinal compartments complying with 11B-605.5 within a multiple accommodation...
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations shall not be located in toilet compartments complying with Section 11B-604.8 or urinal compartments complying with 11B-605.5 within a multiple accommodation...