[See subsections ...]
Search Results "Pedestrian Facility"
-
Common ADA Problems at Newly Constructed Lodging Facilities
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
68.54. Review and Inspection of Buildings and Facilities with an Estimated Construction Cost of Less than $50,000 or Not Subject to the Act
Review and Inspection of Buildings and Facilities with an Estimated Construction Cost of Less than $50,000 or Not Subject to the Act....
-
R302.4 Passing Spaces
Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
-
R305 Detectable Warning Surfaces (Section-by-Section Analysis)
The detectable warning surfaces must contrast visually with adjacent gutter, street or highway, or pedestrian access route surface, either light-on-dark or dark-on-light....
-
28 CFR Part 36, Appendix B: Preamble to Regulation on Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities (1991 ADA Title III Regulations Preamble)
B Appendix B to Part 36 -- Preamble to Regulation on Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities (Published July 26, 1991) Note...
-
Wheelchairs and Other Power-Driven Mobility Devices
Such devices include Segways®, golf cars, and other devices designed to operate in non-pedestrian areas....
-
Small governmental jurisdictions affected by proposed accessibility guidelines
Many of these small governmental jurisdictions are located in rural areas, which generally do not construct pedestrian transportation networks (e.g., sidewalks, pedestrian street crossings...
-
General (R304.1) (Section-by-Section Analysis)
Blended transitions are raised pedestrian street crossings, depressed corners, or similar connections between the pedestrian access route at the level of the sidewalk and the level of the...
-
Challenges in Choosing ADA-Compliant Products
Hi everyone, I’m currently working on a project where we need to select products that are fully ADA-compliant for our new facility....
- Roadtech Manufacturing Retractable Cone Bar Barricades and Barriers
- SDC EntryCheck® E70 Series Standalone Electronic Locksets
-
R404.1 General
Clear spaces are required at operable parts (see R403.2), including accessible pedestrian signals and pedestrian pushbuttons (see R209) and parking meters and parking pay stations that serve...
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Passing Spaces (R302.4) (Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals...
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
Common Requirements (R304.5) (Section-by-Section Analysis)
At pedestrian street crossings without yield or stop control and at midblock pedestrian street crossings, the cross slope is permitted to equal the street or highway grade....
-
R305.1.3 Contrast
Detectable warning surfaces shall contrast visually with adjacent gutter, street or highway, or pedestrian access route surface, either light-on-dark or dark-on-light....
-
Reduced scoping for public accommodations, small facilities, and qualified small businesses. (Section-by-Section Analysis)
be appropriate for barrier removal: play areas, swimming pools, wading pools, saunas and steam rooms, exercise machines, team or player seating areas, areas of sport activity, boating facilities...
-
203 General Exceptions
(203.7) and residential facilities (203.8), employee work areas (203.9), and various spaces within recreation and sports facilities (203.10 through 203.14)....
-
F247.1 General
Where a trail is designed for use by hikers or pedestrians and directly connects to a trailhead or another trail that substantially meets the requirements in 1017, the trail shall comply...
-
R309.4 Curb Ramps or Blended Transitions
Curb ramps or blended transitions complying with R304 shall connect the access aisle to the pedestrian access route. Curb ramps shall not be located within the access aisle....
-
F247.1 General
Where a trail is designed for use by hikers or pedestrians and directly connects to a trailhead or another trail that substantially meets the requirements in 1017, the trail shall comply...
-
Section 36.404 Alterations: Elevator Exemption (Preamble, Section-by-Section Analysis)
Section 36.404 Alterations: Elevator Exemption Section 36.404 implements the elevator exemption in section 303(b) of the Act as it applies to altered facilities....
-
R302.7.4 Flangeway Gaps
Flangeway gaps at pedestrian at-grade rail crossings shall be 64 mm (2.5 in) maximum on non-freight rail track and 75 mm (3 in) maximum on freight rail track....