Section 603.2.2 covers the current ADA Standards for overlapping clear floor space at fixtures and turning spaces in toilet and bathing rooms.
Search Results "Door Maneuvering Clearance"
-
Overlap: ADA Standard Section 603.2.2
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
11B-208.3.3.2
Attached private garages directly serving a single residential dwelling unit shall provide at least one of the following options: A door leading directly from the residential dwelling...
-
11B-208.3.3.2
Attached private garages directly serving a single residential dwelling unit shall provide at least one of the following options: A door leading directly from the residential dwelling...
-
ACCESS AISLE
[DSA-AC] An accessible space adjacent to or between vehicle spaces that provides clearances in compliance with this code....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
- Figure 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling Units – Drawing from the U.S. Access Board
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
11B-404.2.11 Vision lights
Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
-
Identification: ADA Standard Section 809.5.5.2
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
References
to use elements such as at doors, fixtures, and telephones....
-
Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)
Voting Area: There is insufficient maneuvering clearance in front of voting station (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3)....
- Door King Inc. 1812 Access Plus Communication System
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
Portable Floor Lifts
While these lifts may be less expensive than overhead lifts, they require more maneuvering space in the room and space for storage....