M301.4 Lift Compatibility M01.4.1 Clearance in Base Proposed requirement: The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm)...
Search Results "Door Maneuvering Clearance"
-
M301.4 Lift Compatibility
- Caroline's Cart - Making Mobility Easy
-
§382.65(c)(2)
(2) The chair must be designed to be compatible with the maneuvering space, aisle width, and seat height of the aircraft on which it is to be used, and to be easily pushed, pulled, and turned...
-
Compartment: ADA Standard Section 409.4.7.3
Section 409.4.7.3 covers the current ADA Standards for the emergency communication system compartment in private residence elevators.
- ADA Sign Depot California Title 24 Unisex Restroom Door Sign Circle and Triangle - 12" x 12"
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
§ 37.42(e)(2)
(2) If the six-foot clearance is not feasible (e.g., where such a clearance would create an insurmountable gap on a mini-high platform or where the physical structure of an existing station...
-
§ 37.42(e)(2)
(2) If the six-foot clearance is not feasible (e.g., where such a clearance would create an insurmountable gap on a mini-high platform or where the physical structure of an existing station...
-
Kitchen Counters, Walls, and Floors
Staggered stud construction to prevent noise transmission to other rooms Zero clearance kitchen entries with less than 1/4” change of elevation throughout the accessible route. ...
-
§ 38.77(b)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
Operable Parts: ADA Standard Section 611.3
Section 611.3 covers the current ADA Standards for the operable parts of washing machines and clothes dryers.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309....
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309....
-
18(b)
with ADA Standards § 9.3 will be achieved by providing visual alarms connected to the building emergency alarm system, and visual notification devices for incoming telephone calls and door...
-
18(a)
with ADA Standards § 9.3 will be achieved by providing visual alarms connected to the building emergency alarm system, and visual notification devices for incoming telephone calls and door...
-
Landings [4.8.4]
Landings at the top and bottom and intermediate landings, must be at least 60 inches long so maneuvering space is available for approaching ramps straight on....
-
Top Landing [§406.4]
Side flares, where provided, are intended primarily to prevent tripping hazards, not to accommodate wheelchair maneuvering at ramps (except in alterations where sufficient landing space...
-
Fixtures
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
-
§ 38.127(a)
(a) Sleeping compartments required to be accessible shall be designed so as to allow a person using a wheelchair or mobility aid to enter, maneuver within and approach and use each element...
-
11B-809.7 Accessible routes
The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and exterior decks and balconies....
-
11B-809.7 Accessible routes
The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and exterior decks and balconies....
-
11B-604 Water closets and toilet compartments
routes, clear floor space and clearances required at other fixtures, and the turning space....
-
11B-611.3 Operable parts
Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with Section 11B-309....