EXCEPTIONS: 1....
Search Results "Enhanced 9-1-1"
Commonly Searched Documents
-
T302.3 Openings
-
Implication for Standards and Design
Close to 200 community dwelling adults who independently transfer have been evaluated during phases 1 and 2 combined of this multi-year study. ...
-
Is a transportation operator required to procure vehicles with lifts that have a design load of more than 600 pounds?
than 600 pounds, or the platform and vehicle will accommodate a wheelchair that exceeds the dimension of 30 inches by 48 inches, the operator must carry the wheelchair and its occupant.1...
-
J. Bedside Clearance
[ADA Stds. 9.2.2(1)] Yes __ No __ N/A __ Comments: _____________________________________ ...in accessible guestrooms with two beds next to one another, is there a minimum of 36" between...
-
A. Complaint Procedures and Complaints Resolution Officials (CRO’s)
The toll-free number for the hotline is 1-800-778-4838 (voice) and 1-800-455-9880 (TTY)....
-
410.5 Digital Encoding of Speech (Section-by-Section Analysis)
encoded speech in the manner specified by ITU-T Recommendation G.722, a consensus standard for encoding and storing digital audio information that is incorporated by reference in 508 Chapter 1...
-
4.1.3(19)(a)
shall be provided consistent with the following table: Capacity of Seating in Assembly Areas Number of Required Wheelchair Locations 4 to 25 1...
-
2.2.1 Demographic Information
A checklist was used to evaluate these device attributes (see Figure 2‒1)....
-
C. Defendants' Transaction Counter
ECF 106 at 1. “Two cash registers are located on the transaction counter and adjacent to each cash register is space provided for customers to make their transaction.” Id. at 1-2....
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails and Beach Access Routes
Federal agencies shall document the basis for not fully complying with a specific provision in 1017 or 1018 on a portion of a trail or beach access route based on Exception 1 in 1017 or...
-
4.10.4 HALL LANTERNS
Visible signals shall have the following features: (1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor....
-
1.1.12 Ramp cross slope
This method of establishing the running slope and cross slope is consistent with the requirements of ADA/ABA - AG, which gives the standard for running slope and cross slope as 1:12 and...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Exceptions: 1. Accessible routes serving floating boarding piers shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 11B-1003.2.1. 2....
-
11B-211.2 Minimum number
The 2016 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-211.2 Minimum number
The 2019 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
306.3.2 Maximum Depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
306.3.2 Maximum Depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
11B-306.3.2 Maximum depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (229 mm) above the finish floor or ground....
-
306.3.2 Maximum Depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
306.3.2 Maximum Depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
11B-306.3.2 Maximum depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (229 mm) above the finish floor or ground....
-
11B-306.3.2 Maximum depth
Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (229 mm) above the finish floor or ground....
-
Appendix 4 – References
AS1428.1-2001 Design for access and mobility—Part 1: general requirements for access—new building work. Sydney, Australia: Standards Australia International....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....