The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
Commonly Searched Documents
-
602.5 Spout Location
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
R409.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 32 mm (1.25 in) minimum and 51 mm (2 in) maximum....
-
11B-903.3 Size
Benches shall have seats that are 48 inches (1219 mm) long minimum and 20 inches (508 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-903.3 Size
Benches shall have seats that are 48 inches (1219 mm) long minimum and 20 inches (508 mm) deep minimum and 24 inches (610 mm) deep maximum....
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
202.4.2 Accessible Features in the Event of Disproportionality
necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent...
-
Alterations to cells. (Section-by-Section Analysis)
In section 232.2 of the 2004 ADAAG, the Access Board deferred one decision to the Attorney General, specifically: "Alterations to cells shall not be required to comply except to the extent...
-
C. Executive Order 13132: Federalism
Executive Order 13132: Federalism Executive Order 13132 of August 4, 1999, Federalism, directs that, to the extent practicable and permitted by law, an agency shall not promulgate any...
-
Q. Must employers be familiar with the many diverse types of disabilities to know whether or how to make a reasonable accommodation?
Accommodations must be made on an individual basis, because the nature and extent of a disabling condition and the requirements of the job will vary in each case....
-
§ 37.9(b)
This paragraph applies only to alterations of individual elements and spaces and only to the extent that provisions covering those elements or spaces are contained in UFAS or ANSI A117.1...
-
General: ADA Standard Section 702.1
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1), except that the maximum...
-
Ground Level: ADA Standard Section 1008.2.4.1
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
Handrails: ADA Standard Section 1009.3.3
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1008.2.4.1 Ground level
The clear width of accessible routes shall be permitted to be 36 inches (914 mm) minimum for a distance of 60 inches (1524 mm) maximum provided that multiple reduced width segments are separated...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....