Comments from industry noted that such a requirement would increase space requirements at wheelchair seating areas. Response....
Search Results "Supplemental Requirement"
-
Wheelchair Spaces
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
-
11B-208.2.1 Hospital outpatient facilities
employee lot according to the general scoping requirement in Table 11B-208.2....
-
§35.130 General prohibitions against discrimination (Section-by-Section Analysis)
The requirements of this part, including the general prohibitions of discrimination in this section, the program access requirements of subpart D, and the communications requirements of...
-
11B-208.2.1 Hospital outpatient facilities
employee lot according to the general scoping requirement in Table 11B-208.2....
-
11B-208.2.1 Hospital outpatient facilities
employee lot according to the general scoping requirement in Table 11B-208.2....
- The Family Cafe
- Tax Benefits for Businesses Who Have Employees with Disabilities
- Assisted Living Directory - Arkansas Assisted Living Facilities & Senior Care
- Rehabilitation Research and Training Center on Developmental Disabilities and Health
- Ability Found
- Independent Living Resource Center, Inc. (ILRC) - Jefferson City, MO
- International Society of Wheelchair Professionals (ISWP)
-
Check-Out Aisles and Sales and Service Counters
The nondiscrimination requirements of the ADA regulations require the level of service provided at the accessible portion of any sales and service counter to be the same as the level of...
-
229 Windows
229 Windows A new requirement at section 229.1 of the 2010 Standards provides that if operable windows are provided for building users, then at least one window in an accessible space...
-
11B-206.4.4.3 Key stations and intercity rail stations
Key stations and existing intercity rail stations required by Subpart C of 49 CFR part 37 to be altered, shall have entrances complying with Section 11B-404....
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
Lines of Sight at Dining Areas in Sports Venues
Under this exception, access is not required to all dining areas, as is otherwise required....
-
B. M301 Diagnostic Equipment Used by Patients in a Supine, Prone, or Side-lying Position and M302 Diagnostic Equipment Used by Patients in a Seated Position
In the final rule M301 and M302 provide the technical requirements for diagnostic equipment used in the supine, prone, or side-lying position, and diagnostic equipment used by patients in...
-
1007.2.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
405.9 Edge Protection
Edge protection shall not be required on ramps that are not required to have handrails and have sides complying with 406.3. 2....
-
Outdoor Constructed Features Along Trails [F247.5]
percent, but no less than one, of each type of element provided at each location on the trail (other than within camping and picnic facilities and viewing areas, which have their own scoping requirements...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1016.8.4 Turning Space
This section requires a turning space complying with 304.2.3 of the Architectural Barriers Act Accessibility Guidelines where resting intervals are provided adjacent to an outdoor recreation...