protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor or ground surface...
Search Results "Check Writing Surface"
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
-
Walk
An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts....
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground....
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor or ground surface...
-
1007.2 Accessible Routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1....
-
2. Follow the Accessibility Standards for Play Areas
The accessibility standards are minimum standards and do not require the entire play surface area to be accessible....
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
Q7: Curb Ramp for a Sidewalk that is Not Made of Concrete or Asphalt
A7: The Joint Technical Assistance states that "the ADA does not require installation of ramps or curb ramps in the absence of a pedestrian walkway with a prepared surface for pedestrian...
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
A number of commenters from the building industry objected to the provision of the Option One guidelines that specified that an exterior deck, balcony, patio, or similar surface may be no...
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
11B-705.1.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with Section 11B-705....
-
f-ii
Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No...
-
B7-a
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
BOAT LAUNCH RAMP
[DSA-AC] A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
- State of California Disability Access Services (DAS) - Digital Access: Websites, Documents & Section 508
- RI Global
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-705.1.1.1 Dome size
Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and...
-
Standards
when Considering Footwear Traction ASTM F 1637 - 02 Standard Practice for Safe Walking Surfaces ASTM F 1951 - 99 Wheelchair Work Measurement Method ASTM PS 83 -...
-
M301.4.2 Clearance Around Base (Section-by-Section Analysis)
The proposed rule required a minimum clearance of 6 inches high measured from the floor and 36 inches deep measured from the edge of the examination surface. NPRM, 77 FR at 6927....
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground. ...