provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
Search Results "Check Writing Surface"
-
M301.4.1 Clearance in Base
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
2. Mirrors
Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor....
-
e-i
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
5.7.1 Lift Compatibility Clearance in Base for M301
effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise the patient onto and off examination surfaces...
-
11B-705.1.1.3.1
Detectable warning surfaces shall be yellow and approximate 33538 of SAE AMS-STD-595A....
-
Folding Seats on Equipment Used by Patients Seated in a Wheelchair (M302.4 Exception)
However, the folding seat would be required to meet the other technical criteria in M302 for transfer surfaces and supports. Question 28....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
Analysis) The National Federation of the Blind was a member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning surfaces...
-
Animal Containment Areas
These areas must comply with all ADAAG requirements, except the requirements that surfaces be stable, firm, and slip resistant and the restrictions on changes in level since some surfaces...
-
11B-705.1.1.3.1
11B-705.1.1.3.1 Detectable warning surfaces shall be yellow and approximate FS 33538 of Federal Standard 595C....
-
Pedestrian Circulation Path
A prepared exterior or interior surface provided for pedestrian travel in the public right-of-way....
-
106.5.13 Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
Automated Airport Kiosk Definition and Applicability Based on Function/Location
21, 2011, addressing ticket scanners, ITI sought further clarification of how accessibility requirements apply to kiosks based on their functionality and location at the airport (e.g., check-in...
-
Lift Compatibility (M301.4 and M302.4)
A patient lift may be the only means of providing access to certain equipment that cannot meet the technical criteria for transfer surface height (see M301.2.1 and M302.2.1) because of the...
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-1007.3.2 Golf club reach range area
This includes accessible routes provided adjacent to or, where provided, on the playing surface of the hole. ◼ ...
-
11B-705.1.2.3 Islands or cut-through medians
cut-through less 2 inches (51 mm) maximum on each side, placed at the edges of the pedestrian island or cut-through median, and shall be separated by 24 inches (610 mm) minimum of walking surface...
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
- Speakman SensorFlo AC Powered Sensor Faucet S-9020-CA
-
PLACE OF PUBLIC ACCOMMODATION
basis; (3) Availability of housekeeping or linen service; and (4) Acceptance of reservations for a guest room type without guaranteeing a particular unit or room until check-in...
