Where seating is provided in saunas and steam rooms, at least one bench shall comply with 903. Doors shall not swing into the clear floor space required by 903.2....
Search Results "Seat Width"
Commonly Searched Documents
-
612.2 Bench
-
612.2 Bench
Where seating is provided in saunas and steam rooms, at least one bench shall comply with 903. Doors shall not swing into the clear floor space required by 903.2....
-
5.2 Counters and Bars
Where food or drink is served at counters exceeding 34 in (865 mm) in height for consumption by customers seated on stools or standing at the counter, a portion of the main counter which...
-
4.8.5* Handrails
Handrails are not required on curb ramps or adjacent to seating in assembly areas. Handrails shall comply with 4.26 and shall have the following features:...
- Pilot Rock End Accessible Multi-Pedestal Table APT Series 3"x4" Recycled Plastic
-
Protruding Objects and Outdoor Recreation Access Routes
Protruding objects are defined as constructed features (such as signs) that extend into the clear width area of an outdoor recreation access route, resting interval, or passing space and...
-
1016.4 Passing Spaces
This section requires passing spaces to be provided at intervals of 200 feet maximum where the clear width of outdoor recreation access routes is less than 60 inches....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
Openings [1016.6]
Where possible, drainage grates should be located outside the minimum clear width of the ORAR....
-
Maintaining Accessibility in Museum Shops
Museum shops must not allow merchandise to spill into aisles and narrow the width of the accessible route....
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
Clearances for Side Approaches
These clearances, which are permitted to overlap, may determine the width of corridors, including entry alcoves with offset doors....
-
Seeger et al.
Both unoccupied and occupied dimensions of device width and length were measured as well as a set of other basic dimensions....
-
9.5 LOCKER ROOMS
Unobstructed aisle space in front of lockers used by handicapped people shall be a minimum of 42 in (1065 mm) clear width....
-
§ 38.159(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch (16 mm) in width....
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
III. Handrails and Stanchions
Of course, such a handrail or stanchion cannot encroach upon the required 32 inch width required for the doorway or the route leading to the clear floor space which must be at least 30 by...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
I. Relief for Aggrieved Persons:
Upon the execution of a waiver and release form provided by PSE, PSE shall provide each of two individuals, Peter Berg and Yvonne Hengesbaug, with (4) tickets for accessible or companion seats...
-
§ 37.101(b) Fixed Route System. Vehicle Capacity Over 16
If the entity operates a fixed route system and purchases or leases a vehicle with a seating capacity of over 16 passengers (including the driver) for use on the system, it shall ensure...