Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided....
Search Results "Maneuvering Space"
Commonly Searched Documents
-
11B-225.3.1 Dispersion
-
Re: 404.2.6 Doors in Series and Gates in Series
To summarize my opinion, you need compliant door maneuvering clearance at each door, AND space to avoid fighting two doors at once....
-
Location: ADA Standard Section 502.3.4
Section 502.3.4 covers the current ADA Standards for the required location of access aisles.
-
Miscellaneous Elements
MISCELLANEOUS ELEMENTS Fire alarm systems: visible alarms 11B-215, 11B-702 Assistive Listening...
-
Miscellaneous Elements
MISCELLANEOUS ELEMENTS Fire alarm systems: visible alarms 11B-215, 11B-702 Assistive Listening...
-
H. Your Obligation to Provide Services and Equipment
footrests, armrests which are movable or removable, adequate occupant restraint systems, a backrest height that permits assistance to passengers in transferring, structurally sound handles for maneuvering...
-
11B-502.6.4.2
The parking space shall be outlined in blue or painted blue and shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 a minimum 36 inches wide...
- Comfort Designs Tamper Proof Anti-ligature Grab Bars
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
Carpet [§302.2]
Carpet [§302.2] Carpet that is thick, cushiony, or loose impairs accessibility, particularly wheelchair maneuvering....
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9. ...
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9....
-
Minimum Number: ADA Standard Section 208.2
Section 208.2 of the ADA Standards coversscoping requirements in the most current ADA Standards for the minimum number of parking spaces required.
-
Fair Housing Act
The Fair Housing Act also requires landlords to allow tenants with disabilities to make reasonable access-related modifications to their private living space, as well as to common use spaces...
-
Doors in a Series
Section 404.2.6 specifies the minimum separation between doors and gates in series (48 inches plus the width of doors or gates swinging into the space)....
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Self-Service Storage Facilities: ADA Standard Section 225.3
Section 225.3 covers scoping requirements in the current ADA Standards for self-service storage facilities.
-
11B-208.3.1 General
Exceptions: All van parking spaces shall be permitted to be grouped on one level within a multi-story parking facility....
-
Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)
Voting Area: There is insufficient maneuvering clearance in front of voting station (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3)....
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
-
9.2* POST OFFICE LOBBIES
Clear passageways in front of customer service counters shall be not less than 48 in (1220 mm) clear width to permit maneuvering of a wheelchair....
-
11B-208.2 Minimum number
Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking...
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....