Methodology and Data Analysis Data Collection Best practices design solutions were identified from several sources including expert informants who were involved in the design or implementation...
Search Results "Floor Designation"
Commonly Searched Documents
-
Methodology and Data Analysis
-
Additional Training Modules (Call ETA for details)
Assistant® Software (20 - 120 minutes) Designing Accessible Children’s Facilities (15 - 60 minutes) Designing Accessible Toilet Rooms (may include state requirements, if...
- BEA Inc. LZR Microscan Installation Video
-
Test Procedures
The procedures are based on the draft national standard test method for the firmness and stability of ground and floor surfaces (RESNA 2000), which uses an average of five readings....
-
Lockers: ADA Standard Section 225.2.1
Section 225.2.1 covers scoping requirements in the current ADA Standards for lockers.
-
Practice Putting Greens, Practice Teeing Grounds, and Teeing Stations at Driving Ranges: ADA Standard Section 238.3
Section 238.3 covers scoping requirements in the ADA Standards for practice putting greens, practice teeing grounds, and teeing stations at driving ranges.
-
11B-238.3 Practice putting greens, practice teeing grounds, and teeing stations at driving ranges
At least 5 percent, but no fewer than one, of practice putting greens, practice teeing grounds, and teeing stations at driving ranges shall be designed and constructed so that a golf car...
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates...
-
PUBLIC USE
Examples of public use areas may include a hotel lobby, movie theater, concert hall, public restroom, sales floor of a retail store, or dining room within a restaurant. ◼...
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
Number of Accessible Entrances
The proposed rule required that at least one accessible entrance be a ground floor entrance (206.4.3)....
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
General: ADA Standard Section 224.1
Section 224.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for transient lodging guest rooms.
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
11B-411.2.1.1 Location
On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....