The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
Search Results "Transfer Technique"
Commonly Searched Documents
-
1009.4.2 Height
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
Surface
Surface Since people using transfer walls are in bathing suits, their skin may be in contact with the wall....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
On diagnostic equipment used by patients in a seated position, M302.2.2 would require the size of the transfer surface to be 21 inches wide minimum and 15 inches deep minimum....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices....
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface....
-
M301.2.1 Transfer Surface Height
M301.2.1 Transfer Surface Height Subcommittee Recommendation: The imaging subcommittee decided to not specifically come up with a recommendation for transfer height, rather leaving...
-
M302.2 Transfer Surface
M302.2 Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short...
-
Sloped Surfaces
Measuring the slope of a ramp, parking space, pedestrian route, or other ground or floor surface is important to identify whether the surface is accessible. Two slope measurements...
-
Completing Measurements and Recording Information
One person can complete a survey of a polling place but it is often quicker and easier for two people to work together. One can be responsible for taking the measurements and the...
-
2. Electronic (Digital) Level
The slope of a curb ramp or a walkway can make or break its accessibility. People who use wheelchairs, walkers, and other mobility devices cannot safely use a curb ramp, walkway, or...
-
Taking Photographs
It is always useful to first take a photo that will clearly identify the site, then the elements surveyed. A comprehensive set of photographs makes it easier to understand existing...
-
Using the Tape Measure
A tape measure is used to measure the length, width, height, and depth of various elements including parking spaces and access aisles, routes, thresholds, doorways, and protruding...
-
Measuring Opening Force
Measuring Opening Force The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of...
-
2.2.1
List all applicable industry standards that define tolerances and measurement protocols, if any.
-
Compilation of Instruments and Measurement Methods for Surface Accessibility
Compilation of Instruments and Measurement Methods for Surface Accessibility During the course of this project the following information was developed as background information to...