The seat shall be 16 inches (406 mm) wide minimum.
Search Results "Overhead Track Patient Lift"
-
11B-1009.2.5 Seat width
-
F207.2 Platform Lifts
Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International...
-
PREFERRED COMMUNICATION: IDENTIFIES METHODS BY WHICH PATIENTS WANT TO RECEIVE COMMUNICATIONS AND INFORMATION:
PREFERRED COMMUNICATION: IDENTIFIES METHODS BY WHICH PATIENTS WANT TO RECEIVE COMMUNICATIONS AND INFORMATION:...
- Harmar TG400 Toe Guard Commercial Platform Lift
-
Cross Section of Gripping Surfaces
The Access Board is considering whether the above cross section dimensions would be appropriate for the gripping surfaces of transfer supports on diagnostic equipment used by patients in...
-
Master Bedroom
blow if a fall occurs Quilted fabric wall and carpet to absorb ambient noise Duvet covers (make the bed with one hand) Opening in the door frame to accommodate a lift...
-
§ 38.159(b) Vehicle lift
(b) Vehicle lift—...
-
§ 38.125(b) Car lift
(b) Car Lift—...
-
§ 38.23(b)(1) Design load
The design load of the lift shall be at least 600 pounds....
-
§ 38.83(b)(1) Design Load
The design load of the lift shall be at least 600 pounds....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level....
-
1003.2.13.4 Platform lifts
Platform (wheelchair) lifts shall not serve as part of an accessible means of egress, except where allowed as part of a required accessible route in Section 1108.7....
-
Height
Access Board is considering whether 6 inches minimum and 19 inches maximum above the transfer surface would be an appropriate height for transfer supports on diagnostic equipment used by patients...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat surface,...
-
4. Exception from the Requirements of M301 for Certain Examination Chairs that Comply with M302
The Access Board proposed in M101.2 in the MDE NPRM to require diagnostic equipment to meet the standards for each patient position supported, meaning that if diagnostic equipment was designed...
-
Clearances Around Gripping Surfaces
The Access Board is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine...
-
M303 Diagnostic Equipment Used by Patients Seated in Wheelchair
M303 provides technical criteria for diagnostic equipment used by patients seated in a wheelchair....
-
Positioning Supports Considered
in a supine, prone or side-lying position, and diagnostic equipment used by patients in a seated position that can be adjusted to a reclined position....
- Aqua Creek EZ Pool Lift Video
- Midmark 630 HUMANFORM™ Procedures Table
-
5.6.1 Stirrups Provision for M301
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs....